Copper Alloys and MIC

Because copper is toxic to many life forms it is often assumed that copper and its alloys do not suffer from microbially influenced corrosion (MIC).  This is not true and there are a number of ways that bacteria can affect the corrosion of copper alloys, and not all of them are detrimental.

In seawater, aluminium brass forms a protective film of hydrotalcite (Mg6Al2[OH16]CO3.4H2O), which is composed of a minor constituent of the alloy and of seawater.  This film does not form in synthetic seawater, and it is produced because natural seawater contains bacteria that chelate the copper and zinc dissolving from the alloy, and preventing them from becoming incorporated into the protective film.  This film adjusts its composition to buffer the pH at the metal surface and reduce metal dissolution.

Copper alloy corrosion can be greatly accelerated when sulphides are present, particularly in aerated waters. Sulphides are frequently generated by sulphate reducuing bacteria.  These bacteria do not usually produce sulphide on copper alloy surfaces, but become active under deaerated conditions, for example, stagnant enclosed water.  Hence the sulphide is often produced upstream of the copper alloys and the sulphide contacts them when flowing conditions resume.

Posted on: 21st June 2017

Pump Velocities

When calculating the water velocitiy in a centrifugal pump, it is common to calculate the rotation speed of the outer edge of the impeller and quote this as the maximum flow velocity.  However, this gives far too high a velocity than actually occurs in service.  This is because the water in this region is also moving, although not as fast as the impeller.

A more reliable way to calculate the water velocity seen by the pump materials is to recognize that most impellers have vanes that follow a logarithmic spiral (or close to it).  The properties of this curve are that the flow velocity between the vanes is approximately constant, because as the cross sectional area between the vanes increases, the water is accelerating.  Hence, the maximum water velocity can be calculated from the liquid flow from the impeller and the cross sectional area of the impeller at the circumference.

In many water pumps this velocity is 4 to 5 m/s and explains why nickel aluminium bronze works so well in this application, when it would not at the 10 - 20m/s velocity calculated from the rotation speed of the impeller circumference.

Posted on: 7th June 2017

Rapid Tests for Anions and Cations

When trying to determine the cause of corrosion it is common to examine a sample in the SEM and analyse the corrosion products.  However, this only detects elements and cannot tell if the sulphur is present as sulphide or sulphate, for example.

There is a quick and simple way to test for many species using spot tests.  All of the ones below were taken from "Spot Tests in Inorganic Analysis" by F Fiegl, published by Elsevier, 2nd edition, 1958.  There are probably more recent editions.  All you need to do is to scrape a small sample of corrosion product onto a glass slide, add a drop or two of the test solution and observe under a low power microscope (X10 or X20).

SULPHIDE - This is readily detected with the sodium azide test and it is not only specific for sulphide, it is also very sensitive.  The rate at which nitrogen bubbles evolve in the solution gives an indication of the quantity of sulphide, from a trace to a large quantity.

CHLORIDE - If you suspect chloride has entered a system where it was not expected, the silver nitrate test is also very sensitive to chloride and the amount of white precipitate indicates how much chloride is present.

AMMONIA- this is a more fiddly test and must be done very quickly after removal as ammonia is so volatile.  However, I have used this to demostrate ammonia-induced crevice corrosion in copper-nickel heat exchanger tubes.

There are lots of tests for other anions and cations and many are very specific and they are all quick to do.  Make sure you test the solution on something of known composition before using, as some of the test solutions can go off, when exposed to daylight, or just with time.

Posted on: 21st May 2017

Sulphur and Sulphides

It is well known that the corrosion of copper alloys in aerated seawater is greatly accelerated when small amounts of sulphide (eg cysteine or hydrogen sulphide) are also present.  As little as 0.02 mg/L sulphide can greatly increase corrosion and cause rapid failure of heat exchanger tubes.


However, if the seawater feed lines are long (> 100m) the dissolved oxygen in the seawater reacts with the sulphide to form elemental sulphur.  This is less aggressive to copper alloys compared with sulphide although the reduction in severity varies with alloy, as shown in the table below.  This data was generated at BNF Metals Research Association in the 1950s but was never published in the open literature.

Depth of Impingement Attack in Seawater using the BNF Jet Test at 5m/s and 20°C

Posted on: 7th May 2017

Etching of Duplex Stainless Steels

Modern duplex stainless steels have a phase balance around 50/50 austenite/ ferrite and many specifications require the ferrite content to be determined.  A common requirement is to etch electrolytically in 40% NaOH or KOH, because this stains the ferrite light brown and makes ferrite determination easier.  However, this etch does not clearly show grain boundaries or third phases, such as sigma, chi and nitrides.  These are best shown by first etching in 10% oxalic acide followed by the hydroxide stain etch (see below).  If the microstructure is viewed by polarised light or bright field illumination, the sigma/chi phases appear orange.  Nitrides appear as black dots in the ferrite or decorate the ferrite sub-grain boundaries (see below).

 

       

UNS S32760 showing sigma and chi phases           UNS S32760 showing nitrides in the ferrite

Posted on: 21st April 2017